THERMAL-HYDRAULIC CHARACTERIZATION OF METAL ADDITIVELY MANUFACTURED WICKS
| dc.contributor.advisor | Kempers, Roger | |
| dc.contributor.author | Hasan, Mohamed Ahmed | |
| dc.date.accessioned | 2026-11-06T16:13:19Z | |
| dc.date.available | 2026-11-06T16:13:19Z | |
| dc.date.copyright | 2026-08-13 | |
| dc.date.issued | 2026-11-06 | |
| dc.date.updated | 2026-11-06T16:13:19Z | |
| dc.degree.discipline | Mechanical Engineering | |
| dc.degree.level | Doctoral | |
| dc.degree.name | PhD - Doctor of Philosophy | |
| dc.description.abstract | The increasing thermal loads of modern high-performance systems demand efficient two-phase thermal management technologies, such as heat pipes (HPs) and vapor chambers (VCs). Their performance strongly depends on wick structures that provide sufficient capillary pumping while maintaining high permeability and effective thermal transport. Additive manufacturing (AM) enables greater control of wick geometry and provides new opportunities to optimize this balance. This thesis experimentally investigates the hydraulic, capillary, and thermal performance of engineered wick structures fabricated using laser powder bed fusion (LPBF) and electrochemical additive manufacturing (ECAM). LPBF AlSi10Mg lattice wicks exhibited permeabilities ranging from 33.8 to 753.4 µm², with simple-cubic lattices providing the highest permeability. Capillary characterization showed that permeability was the dominant factor governing the capillary performance parameter, . The practical resolution limitations of the LPBF system motivated the investigation of finer LPBF hatched-grooved and ECAM copper lattice wicks. Under saturated thermal testing, the LPBF hatched-grooved wicks achieved a minimum evaporator thermal resistance of 0.115 K/W at 43.5 W/cm². The best-performing ECAM BCC wick achieved approximately 0.09 K/W and sustained the highest operating heat flux, consistent with its favorable capillary transport characteristics. Finally, an integrated LPBF two-phase heat sink demonstrated a 19.2% reduction in overall thermal resistance and approximately 34% mass reduction relative to a conventional solid heat sink. Overall, the results demonstrate the potential of AM to tailor wick transport characteristics and enable lightweight, integrated, high-performance two-phase thermal management devices. | |
| dc.identifier.uri | https://hdl.handle.net/10315/44312 | |
| dc.language | en | |
| dc.rights | Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests. | |
| dc.subject | Mechanical engineering | |
| dc.subject.keywords | Additive manufacturing | |
| dc.subject.keywords | Heat pipes | |
| dc.subject.keywords | Capillary wicks | |
| dc.subject.keywords | Laser powder bed fusion | |
| dc.subject.keywords | Electrochemical additive manufacturing | |
| dc.subject.keywords | Permeability | |
| dc.subject.keywords | Capillary performance | |
| dc.subject.keywords | Effective thermal conductivity | |
| dc.subject.keywords | Evaporator thermal resistance | |
| dc.subject.keywords | Two-phase thermal management | |
| dc.title | THERMAL-HYDRAULIC CHARACTERIZATION OF METAL ADDITIVELY MANUFACTURED WICKS | |
| dc.type | Electronic Thesis or Dissertation |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Hasan_Mohamed_Ahmed_2026_PhD.pdf
- Size:
- 8.97 MB
- Format:
- Adobe Portable Document Format