Transformer Differential Protection Under Geomagnetically Induced Current Conditions

dc.contributor.advisorRezaei-Zare, Afshin
dc.contributor.authorAhmadzadeh-Shooshtari, Babak
dc.date.accessioned2024-11-07T11:00:34Z
dc.date.available2024-11-07T11:00:34Z
dc.date.copyright2023-10-12
dc.date.issued2024-11-07
dc.date.updated2024-11-07T11:00:32Z
dc.degree.disciplineElectrical Engineering & Computer Science
dc.degree.levelDoctoral
dc.degree.namePhD - Doctor of Philosophy
dc.description.abstractSolar activities result in fluctuations in the Earth’s magnetic field, referred to as geomagnetic disturbances (GMDs). During the GMDs, geomagnetically induced currents (GICs) flow through the power transformers with grounded neutrals. The transformers subjected to the GIC experience part-cycle core saturation creating significant magnetizing current harmonics, including dominant second harmonics. The GIC-caused harmonics can pose issues for protection systems, such as transformer differential relays. The majority of real-world transformer differential relays employ harmonic blocking (HB) modules to prevent malfunctions during transformer energization leading to inrush currents containing high levels of second harmonics. Considering that the GIC-related transformer current second harmonics can be significant, the differential relays are prone to be blocked during the GMDs and remain blocked for the faults occurring in their protection zones, which may damage the transformers and threaten the system’s resiliency. This dissertation conducts in-depth time-domain analyses on the performance of differential relays, equipped with various HB logics, for internal/in-zone faults under the GIC conditions. It is revealed that regardless of the employed HB logic, such relays are unwantedly blocked for the faults with specific ranges of fault resistances in the presence of GIC, and therefore, fail to trip for the faults. To address this issue, different unblocking schemes are proposed, which can detect the GIC flow in the transformer and override the blocking signals, generated by the relay’s HB module, during the internal faults. The effectiveness of the developed schemes is extensively investigated to ensure (i) dependability for the co-existence of internal faults and GIC and (ii) security during the GMDs in the absence of faults as well as the transformer energization and external faults, especially under the current transformer (CT) saturation. Moreover, detailed real-time hardware-in-the-loop (HIL) tests verify that a commercial transformer differential relay fails to operate for terminal and transformer turn faults owing to the harmonic blocking during the GIC when the post-fault differential current fundamental component decreases below certain levels. Furthermore, it is shown that the relay equipped with a proposed unblocking scheme is effectively unblocked in real time and operates in the internal fault cases where the commercial relay cannot trip.
dc.identifier.urihttps://hdl.handle.net/10315/42394
dc.languageen
dc.rightsAuthor owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.
dc.subjectElectrical engineering
dc.subjectEnergy
dc.subject.keywordsDifferential protection
dc.subject.keywordsProtective relay
dc.subject.keywordsTransformer
dc.subject.keywordsGeomagnetic disturbance (GMD)
dc.subject.keywordsGeomagnetically induced current (GIC)
dc.subject.keywordsHarmonic blocking (HB)
dc.subject.keywordsUnblocking
dc.subject.keywordsFault
dc.subject.keywordsReal-time test
dc.subject.keywordsCurrent transformer (CT) saturation
dc.subject.keywordsTransformer energization
dc.subject.keywordsInrush current
dc.titleTransformer Differential Protection Under Geomagnetically Induced Current Conditions
dc.typeElectronic Thesis or Dissertation

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ahmadzadeh-Shooshtari_Babak_2023_PhD.pdf
Size:
10.02 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
license.txt
Size:
1.87 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
YorkU_ETDlicense.txt
Size:
3.39 KB
Format:
Plain Text
Description: