Towards High-Throughput High-Frequency CMOS Nuclear Magnetic Resonance Spectroscopy

dc.contributor.advisorKassiri, Hossein
dc.contributor.advisorGhafar-Zadeh, Ebrahim
dc.contributor.authorMansouri, Mahta
dc.date.accessioned2021-11-15T15:19:38Z
dc.date.available2021-11-15T15:19:38Z
dc.date.copyright2021-05
dc.date.issued2021-11-15
dc.date.updated2021-11-15T15:19:38Z
dc.degree.disciplineElectrical and Computer Engineering
dc.degree.levelMaster's
dc.degree.nameMASc - Master of Applied Science
dc.description.abstractDriven by the many of Nuclear Magnetic Resonance (NMR) spectroscopy applications, there is an ever-increasing demand for high-throughput NMR receivers to accelerate the speed and reduce the cost of the NMR spectroscopy. The envisaged solution by the industry is to employ significantly stronger static magnetic fields to achieve higher signal-to-noise ratio (SNR). However, this demands for the system to operate at proportionally-higher frequencies to satisfy the Larmor equation and to be able to shrink the receiver coil size (hence, fit higher number of parallel receivers in the same space) without the loss of SNR. Despite the benefits, a higher frequency of operation introduces several challenges in the design of the receiver's transducer (i.e., coil) and the readout circuitry (i.e., tuning, matching, and amplification circuits). We present the design and optimization of an electromagnetic Radio Frequency (RF) coil along with the readout circuitry both integrated on the same silicon-based platform for fabrication in a standard 0.35-m complementary metal-oxide-semiconductor (CMOS) technology. In the design of the coil, all the important electrical and physical parameters that could affect the NMR spectroscopy's overall performance are analytically identified and taken into account. Additionally, the readout integrated circuit is designed to be compatible with a wide range of on-chip and off-chip coils. The circuit architecture and the design procedure proposed for the readout circuit are adaptable to any frequency of operation. The presented integrated system consists of two channels enabling simultaneous NMR spectroscopy, and has no practical limitations for channel scaling. To the best of our knowledge, this design is the first CMOS-based NMR receiver operating at 500 MHz. While all components are designed and optimized for this frequency, the presented design procedures for both the coil and the readout circuits are applicable to higher frequencies.
dc.identifier.urihttp://hdl.handle.net/10315/38670
dc.languageen
dc.rightsAuthor owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.
dc.subjectElectrical engineering
dc.subject.keywordsNMR
dc.subject.keywordsCMOS
dc.subject.keywordson-chip
dc.subject.keywordsµcoil
dc.subject.keywordsLNA
dc.subject.keywordsSNR
dc.subject.keywordsquality factor
dc.subject.keywordsmagnetic field uniformity
dc.subject.keywordshigh-throughput
dc.subject.keywordshigh-frequency
dc.subject.keywordsspectroscopy
dc.titleTowards High-Throughput High-Frequency CMOS Nuclear Magnetic Resonance Spectroscopy
dc.typeElectronic Thesis or Dissertation

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mansouri_Mahta_2021_Masters.pdf
Size:
3.5 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
license.txt
Size:
1.87 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
YorkU_ETDlicense.txt
Size:
3.39 KB
Format:
Plain Text
Description: