Calibration and Flight of a Balloon-Borne O2 Atmospheric Band Fabry-Perot Spectrometer

dc.contributor.advisorShan, Jinjun
dc.creatorVoutsogiannakis, Michael
dc.date.accessioned2018-03-01T14:11:07Z
dc.date.available2018-03-01T14:11:07Z
dc.date.copyright2017-09-06
dc.date.issued2018-03-01
dc.date.updated2018-03-01T14:11:06Z
dc.degree.disciplinePhysics And Astronomy
dc.degree.levelMaster's
dc.degree.nameMSc - Master of Science
dc.description.abstractThe Fabry-Perot spectrometer is an extremely useful tool for retrieving spectral information of the Oxygen A-band at nadir viewing angles, as well as for remote sensing purposes. Testing the performance of this spectrometer will help us determine possible limitations and improvements needed to be carried out for future missions, so that the scientific objectives can be met successfully. For the calibration setup, a narrow line argon source was used and the procedure was carried out by varying the gap spacing between the etalon plates, thus performing step scans that cover the entire free spectral range. Valuable information can be acquired, such as the reflective Finesse of the etalon, the degree of parallelism and flatness of the plates, as well as the temperature coefficient of the etalon. Measurements were also performed on O2 interference filters, making use of a diffraction grating spectrometer, in order to understand their behavior with temperature change.
dc.identifier.urihttp://hdl.handle.net/10315/34399
dc.language.isoen
dc.rightsAuthor owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.
dc.subjectPhysics
dc.subject.keywordsFabry-Perot
dc.subject.keywordsSpectrometer
dc.subject.keywordsCalibration
dc.subject.keywordsOptics
dc.subject.keywordsFilters
dc.subject.keywordsFinesse
dc.subject.keywordsEtalon
dc.subject.keywordsA-band
dc.subject.keywordsDiffraction grating
dc.subject.keywordsBandwidth
dc.subject.keywordsLens
dc.subject.keywordsInterference
dc.subject.keywordsFree spectral range
dc.subject.keywordsFWHM
dc.subject.keywordsFSR
dc.subject.keywordsStratospheric balloon
dc.subject.keywordsLissberger
dc.subject.keywordsWavelength shift
dc.subject.keywordsTemperature change
dc.subject.keywordsEtendue
dc.subject.keywordsF-number
dc.subject.keywordsFocal length
dc.subject.keywordsSpectrum
dc.subject.keywordsAlbedo
dc.subject.keywordsRadiance
dc.subject.keywordsSlit
dc.subject.keywordsCCD
dc.subject.keywordsTelephoto
dc.subject.keywordsSource
dc.subject.keywordsArgon
dc.subject.keywordsTungsten
dc.subject.keywordsThermocouple
dc.subject.keywordsRTD sensor
dc.subject.keywordsTemperature controller
dc.subject.keywordsPlates
dc.subject.keywordsPiezos
dc.subject.keywordsGap spacing
dc.subject.keywordsStep scan
dc.titleCalibration and Flight of a Balloon-Borne O2 Atmospheric Band Fabry-Perot Spectrometer
dc.typeElectronic Thesis or Dissertation

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Voutsogiannakis_Michael_2017_Masters.pdf
Size:
10.95 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
license.txt
Size:
1.83 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
YorkU_ETDlicense.txt
Size:
3.38 KB
Format:
Plain Text
Description: