Phillips, DevinJamal-Zadeh, Parsa2026-11-062026-11-062026-08-062026-11-06https://hdl.handle.net/10315/44233The high intensity constant work rate cardiopulmonary exercise test (CWR-CPET) has limited evidence establishing its reliability and whether a learning/desensitization effect is prevalent. The objective of this study was to determine the effect of repeated CWR-CPETs on perceptual responses and exercise endurance time (EET). Thirty participants were randomized into a chest-wall strapping (CWS) or free-breathe control condition. Two cycle ergometer incremental CPETs, and 4 consecutive CWR-CPETs at 80% of peak work rate were completed. Exertional breathlessness intensity and leg discomfort were greater in CWS versus control (both p<0.01). Perceived breathlessness and leg discomfort were significantly decreased across CWR trials (both p<0.05), while no effect was observed for key physiological parameters. There was a main effect of test number on EET (p=0.049). Coefficients of variation between consecutive tests and conditions were not different (p>0.05). These data suggest that a learning/desensitization effect is present for the CWR-CPET.Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests.KinesiologyHealth sciencesPhysiologyRepeated Cardiopulmonary Exercise Test Exposure: Implications for Breathlessness and Exercise ToleranceElectronic Thesis or Dissertation2026-11-06BreathlessnessDyspneaCardiopulmonary exercise testingExercise endurance timeTest-retest reliabilityPerceptual responsesLearning effectChest-wall strappingDyspnea desensitization